Method guide

Phased Array Method Guide: Sector, Coverage and TOFD

RAS Thermal Co., Ltd.: the phased array method on blades, the sector it steers, and the pairing with TOFD that covers both defect classes

TL;DR Phased array ultrasonic testing is the method that satisfies IEC 61400-5 at production speed, because a 64-element array steers a 40-70° sector through the thickness and covers a 600 mm spar cap in one pass where a single-element probe would need 20.

Array

64 elements

Sector scan

40-70°

Channels

up to 256

Cap coverage

600 mm in one longitudinal pass

Single-element equivalent

20 parallel passes, about 5x longer

Bandwidth

0.5-10 MHz

The beam control is what changes the economics. A phased array steers and focuses electronically, so the mechanical raster scanning that makes single-element work slow disappears. A 600 mm spar cap falls to one longitudinal pass at 500 mm/s, and the 40-70° sector images separations inclined steeply to the surface that a fixed-angle probe would pass over. Multiply the pass count by five and the single-element route stops fitting a takt time.

The pairing is deliberate rather than incidental. PAUT images planar separations that lie parallel to the plies and it carries the amplitude signature of dry laminate, while TOFD reads volumetric clusters whatever their orientation. Table G.1 caps delamination at 6 mm and a porosity cluster at 3 mm, so a pass that reads only planes can miss a cluster near the tight limit, and a pass that reads only volumes can miss a flat separation. A 256-channel system runs both in one scan.

The number the method is measured against comes from a reference rather than a brochure. A 6 mm squared flat-bottom hole at 20 mm depth in a glass-fibre panel built to ASTM E2580 is the artefact behind the 99.2 % probability of detection, and a 0.5-10 MHz bandwidth on the array lets the same setup interrogate the panel and the blade. That is what makes the detection figure traceable and the amplitude channel comparable from one blade to the next.

Read the figures as sourced, not as marketing. Each one sits in the documentation we already publish on this site.

Options at a glance

MethodReadsLimit it serves
PAUT sector scanplanar separation parallel to plies6 mm delamination
TOFDvolumetric scatter, any orientation3 mm porosity cluster
PAUT amplitudedry laminate and unbonded interfacesnot permitted

How to work through this topic

  1. 01 Fix the acceptance threshold. Start from the threshold the zone carries, not from the method you happen to own. IEC 61400-5 Section 11 asks for volumetric detection of indications 6 mm and larger in the laminate plane, and DNV-ST-0126 tightens the leading edge to 3 mm, so the threshold is set before the probe is chosen.
  2. 02 Read the geometry off the drawing. Measure the thickness and the curvature the probe has to travel. A spar cap up to 80 mm of unidirectional laminate and a root transition of changing radius are two different scan problems, and the radius decides how the array is coupled.
  3. 03 Choose the modality pair. Pick modules by defect geometry, not by habit. PAUT images planar separations that lie parallel to the plies, TOFD catches volumetric clusters whatever their orientation, and running both on a 256-channel system puts the two mechanisms in one pass.
  4. 04 Automate the scan path. Put the probe on an encoder-driven carriage and let the path, not the technician, set coverage. A 600 mm spar cap falls to one longitudinal pass at 500 mm/s on a linear array, where a single-element probe needs 20 parallel passes and runs about five times longer.
  5. 05 Lock the evidence chain. Write the coverage map, the daily calibration and the indication log to the blade serial while the scan is running. It is the difference between a 3-day type-certification audit and a 3-hour document review, and it is what ISO 9712 qualification is there to sign.

Detailed pages in this topic

Frequently Asked Questions

Why is PAUT used on blade spar caps?

Because it steers a 40-70° sector through the thickness and covers a 600 mm cap in one longitudinal pass at 500 mm/s, where a single-element probe would need 20 parallel passes and about five times the time. That is what lets 100 % coverage fit a production cadence.

Why pair PAUT with TOFD?

Because they cover two defect classes with two different limits. PAUT images planar separations against the 6 mm delamination limit, and TOFD reads volumetric clusters against the tighter 3 mm porosity limit, so one pass answers both.

What proves the detection figure?

A 6 mm squared flat-bottom hole at 20 mm depth in a glass-fibre reference panel per ASTM E2580. Reaching 99.2 % probability of detection on that artefact is what ties the method to a known defect rather than a claim.

What sector does the array steer?

A 40-70° sector, which images separations inclined steeply to the surface that a fixed-angle probe would pass over. The sweep happens electronically in one pass rather than by moving the probe by hand.

Standards and sources

Send us the blade type and the zones

Tell us the blade type, the zones and the standard you report against. We will map the scan plan and the evidence chain to your programme.

Talk to an engineer